Labsphere
HalfMoon Light Measurement System
HalfMoon System designed to measure forward emitting lamps, LEDs, board mounted and heat-sinked LED light Engines for Solid State Lighting (SSL).
Features:
  • Larger forward flux emitting light engines measured with half the footprint of a regular integrating sphere system.
  • Lamp standard of forward flux minimizes substitution errors between the lamp standard and the DUT.
  • Radiometric, photometric and colorimetric characterization capabilities.
BEST FOR:
  • LEDs
  • LED Light Engines
  • SSL Fixtures
  • Displays


HalfMoon LED & diplays Light Measurement System
HalfMoon LED & diplays Light Measurement System

Integrating Spheres - US Series
US Serie integrating spheres are Specifically for uniform radiance for the test and calibration of imaging and non-imaging devices.
Integrating Sphere Model
US-060-SF
US-080-SF
US-120-SF
US-200-SF
Sphere Diameter
6 inches
8 inches
12 inches
20 inches
Output Port Diameter
2 inches
2 inches
4 inches
8 inches
Sphere material/Coating
Spectraflect
Spectraflect
Spectraflect
Spectraflect

Integrating Sphere applications :
  • Calibration and testing of Detectors
  • Calibration and testing of Electronic Imaging devices
  • Calibration and testing of CCD Cameras
  • Calibration of Photometers and Radiometers
  • Illumination for Densitometry
  • Illumination of Resolution Targets
  • MTF Testing of Optical Systems
  • Transmittance Measurements of Fiber-optics


Integrating Spheres - US Series
Integrating Spheres - US Series

LMS Series -Light Measurement Integrating Spheres
LMS integrating sphere are Accurate and flexible, Labsphere’s Light Measurement Integrating Spheres are designed to measure the total flux of LEDs, lamps and other light sources.
Model
LMS-100
LMS-200
LMS-400
LMS-650
LMS-760
Sphere Diameter
10 inches (0.25m)
20 inches (0.5m)
40 inches (1m)
65 inches (1.5m)
76 inches (2m)
Max Lamp Length:
5 inches (13cm)
10 inches (25cm)
24 inches (61cm)
34 inches (86cm)
52 inches (1.3m)
Sphere material/Coating
Spectraflect®

Integrating Sphere applications :
  • Light tight closure
  • Base-up or Base-down lamp mounting
  • Socket Mounting Plate
  • Adjustable fluorescent lamp holder
  • Variable height electrical supply tube
  • Interchangeable baffle
  • Temperature sensor mounting port
  • 50mm directional light source or LED port


LMS Series -Light Measurement Integrating Spheres
LMS Series -Light Measurement Integrating Spheres

ModSphere - Integrating Sphere General Purpose
This line is designed to provide greater configuration flexibility than ever before. Choose your sphere by selecting size, ports, and reflectance material.
This flexibility allows you to create your own uniform source or light measurement system, or modify an existing system in a matter of minutes. A variety of system calibration options enable systems to be customized for application specific tasks.

FEATURES :
  • Size: Miniature: 1 - 2 inches / Standard: 3 – 6 inches
  • Reflectance Material:Spectralon®-Spectraflect® coating-Infragold® coating
  • Optional Detector Assemblies: Silicon-Germanium-Indium-Gallium-Arsenide
Best for Calibrating :
  • LED Sourced Systems
  • Solid State Lighting
  • Large-Area LED Display Back lighting
  • General Lighting
  • Automotive Lighting
  • Architectural Lighting


ModSphere - Integrating Sphere General Purpose
ModSphere - Integrating Sphere General Purpose

LPM series -Integrating Spheres - Laser
LPM Series Laser Power Measurement Integrating Spheres collect the total radiant power emitted by highly divergent sources such as laser diodes, as well as collimated sources such as lasers.
Applications :
  • Measure Laser and Laser Diode Output
  • Optical Bench Detection
  • Measure Collimated Light sources
Features :
  • Independent of Beam geometry
  • Collect total power from divergent sources


LPM series -Integrating Spheres - Laser
LPM series -Integrating Spheres - Laser

Reflectance/Transmittance - Integrating Spheres

LPM-040-IG
RT-060-SF
RT-060-IG
RTC-060-SF
RTC-060-IG
Sphere Diameter:
6 inches
6 inches
6 inches
6 inches
Sphere Coating:
Spectraflect®
Infragold®
Spectraflect®
Infragold®
Optimum Spectral Range:
250 - 2500 nm
0.7 μm - 20 μm
250 - 2500 nm
0.7 μm - 20 μm

Best for Measuring :
  • Reflectance and transmittance of materials
  • Reflectance of opaque samples
  • Transmittance of turbid samples
  • Color properties
  • Reflectance system design
  • Infrared reflectance
  • Reflectance vs. angle


Reflectance/Transmittance - Integrating Spheres
Reflectance/Transmittance - Integrating Spheres

Illumia Pro

Simultaneous thermal, optical and electrical characterization of LEDs

FEATURES :
  • Wide dynamic range which allows a single sphere to measure a wide range of light levels
  • NIST traceable standards for in-house recalibration
  • Spectral results in milliseconds
  • Spectraflect interior sphere coating
  • Complete Thermal, Optical & Electrical Analysis
  • TEC Temperature Control and Monitoring
  • Measure Optical Properties as a Function of Temperature and Operating Current
  • Available in 0.5m, 1m, 1.65m, and 1.95m Sphere Diameters
  • Conforms to IESNA LM-79 & LM-80 Measurement Geometries
  • Ambient Air Temperature Control Available
MEASURE :
  • Total Spectral Flux
  • Luminous Flux
  • Radiant Flux
  • Chromaticity
  • CCT and CRI
  • Peak Wavelength
  • Dominant Wavelength
  • I, V, and Luminous Efficacy
  • Thermal: Case Temperature Control vs. Electrical and Optical Parameters
APPLICATIONS :
  • Packaged LEDs
  • Modules & Arrays
  • Backlight Displays
  • Solid State Lighting


Illumia Pro Labsphere

Illumia Systems

Spectral Flux Measurement Systems

FEATURES :
  • Wide dynamic range which allows a single sphere to measure a wide range of light levels
  • NIST traceable standards for in-house recalibration
  • Spectral results in milliseconds
  • Spectraflect® interior sphere coating
  • Available in 25cm, 50cm, 100cm, 165cm, and 195cm Sphere Diameters
  • Conforms to national standard measurement geometries
MEASURE :
  • Total Spectral Flux
  • Luminous Flux
  • Radiant Flux
  • Chromaticity
  • CCT and CRI
  • Peak Wavelength
  • Dominant Wavelength
  • I, V, and Luminous Efficacy
APPLICATIONS :
  • Packaged LEDs
  • Miniature Lamps
  • LED Sourced Systems


LabsphereBrochure_Ix_1 3.pdf