| HalfMoon Light Measurement System |
HalfMoon System designed to measure forward emitting lamps, LEDs, board mounted and heat-sinked LED light Engines for Solid State Lighting (SSL). Features:
- Larger forward flux emitting light engines measured with half the footprint of a regular integrating sphere system.
- Lamp standard of forward flux minimizes substitution errors between the lamp standard and the DUT.
- Radiometric, photometric and colorimetric characterization capabilities.
BEST FOR:
- LEDs
- LED Light Engines
- SSL Fixtures
- Displays
|  |
|
| Integrating Spheres - US Series |
US Serie integrating spheres are Specifically for uniform radiance for the test and calibration of imaging and non-imaging devices.
| |
US-060-SF |
US-080-SF
|
US-120-SF |
US-200-SF |
Sphere Diameter |
6 inches |
8 inches |
12 inches |
20 inches |
|
|
2 inches |
4 inches |
8 inches |
|
|
Spectraflect |
Spectraflect |
Spectraflect |
| Integrating Sphere applications : |
- Calibration and testing of Detectors
- Calibration and testing of Electronic Imaging devices
- Calibration and testing of CCD Cameras
- Calibration of Photometers and Radiometers
|
- Illumination for Densitometry
- Illumination of Resolution Targets
- MTF Testing of Optical Systems
- Transmittance Measurements of Fiber-optics
|
|  |
|
| LMS Series -Light Measurement Integrating Spheres |
LMS integrating sphere are Accurate and flexible, Labspheres Light Measurement Integrating Spheres are designed to measure the total flux of LEDs, lamps and other light sources.
| |
LMS-100 |
LMS-200
|
LMS-400 |
LMS-650 |
LMS-760 |
Sphere Diameter |
10 inches (0.25m) |
20 inches (0.5m) |
40 inches (1m) |
65 inches (1.5m) |
76 inches (2m) |
Max Lamp Length: |
5 inches (13cm) |
10 inches (25cm) |
24 inches (61cm) |
34 inches (86cm) |
52 inches (1.3m) |
|
|
| Integrating Sphere applications : |
- Light tight closure
- Base-up or Base-down lamp mounting
- Socket Mounting Plate
- Adjustable fluorescent lamp holder
|
- Variable height electrical supply tube
- Interchangeable baffle
- Temperature sensor mounting port
- 50mm directional light source or LED port
|
|  |
|
| ModSphere - Integrating Sphere General Purpose |
This line is designed to provide greater configuration flexibility than ever before. Choose your sphere by selecting size, ports, and reflectance material. This flexibility allows you to create your own uniform source or light measurement
system, or modify an existing system in a matter of minutes. A variety of system
calibration options enable systems to be customized for application specific tasks.
FEATURES :
- Size: Miniature: 1 - 2 inches / Standard: 3 6 inches
- Reflectance Material:Spectralon®-Spectraflect® coating-Infragold® coating
- Optional Detector Assemblies: Silicon-Germanium-Indium-Gallium-Arsenide
| Best for Calibrating : |
- LED Sourced Systems
- Solid State Lighting
- Large-Area LED Display Back lighting
|
- General Lighting
- Automotive Lighting
- Architectural Lighting
|
|  |
|
| LPM series -Integrating Spheres - Laser |
LPM Series Laser Power Measurement Integrating Spheres collect the total radiant power emitted by highly divergent sources such as laser diodes, as well as collimated sources such as lasers. Applications :
- Measure Laser and Laser Diode Output
- Optical Bench Detection
- Measure Collimated Light sources
Features :
- Independent of Beam geometry
- Collect total power from divergent sources
|  |
|
| Reflectance/Transmittance - Integrating Spheres |
| |
RT-060-SF |
RT-060-IG
|
RTC-060-SF |
RTC-060-IG |
| Sphere Diameter: |
6 inches |
6 inches |
6 inches |
6 inches |
| Sphere Coating: |
|
Infragold® |
Spectraflect® |
Infragold® |
| Optimum Spectral Range: |
|
0.7 μm - 20 μm |
250 - 2500 nm |
0.7 μm - 20 μm |
| Best for Measuring : |
- Reflectance and transmittance of materials
- Reflectance of opaque samples
- Transmittance of turbid samples
|
- Color properties
- Reflectance system design
- Infrared reflectance
- Reflectance vs. angle
|
|  |
|
| Illumia Pro |
Simultaneous thermal, optical and electrical characterization of LEDs
FEATURES :
-
Wide dynamic range which allows a single sphere to measure a wide range of light levels
- NIST traceable standards for in-house recalibration
- Spectral results in milliseconds
- Spectraflect interior sphere coating
- Complete Thermal, Optical & Electrical Analysis
- TEC Temperature Control and Monitoring
- Measure Optical Properties as a Function of Temperature and Operating Current
- Available in 0.5m, 1m, 1.65m, and 1.95m Sphere Diameters
- Conforms to IESNA LM-79 & LM-80 Measurement Geometries
- Ambient Air Temperature Control Available
MEASURE :
- Total Spectral Flux
- Luminous Flux
- Radiant Flux
- Chromaticity
- CCT and CRI
- Peak Wavelength
- Dominant Wavelength
- I, V, and Luminous Efficacy
- Thermal: Case Temperature Control vs. Electrical and Optical Parameters
APPLICATIONS :
- Packaged LEDs
- Modules & Arrays
- Backlight Displays
- Solid State Lighting
|  |
|
| Illumia Systems |
Spectral Flux Measurement Systems
FEATURES :
-
Wide dynamic range which allows a single sphere to measure a wide range of light levels
- NIST traceable standards for in-house recalibration
- Spectral results in milliseconds
- Spectraflect® interior sphere coating
- Available in 25cm, 50cm, 100cm, 165cm, and 195cm Sphere Diameters
- Conforms to national standard measurement geometries
MEASURE :
-
Total Spectral Flux
- Luminous Flux
- Radiant Flux
- Chromaticity
- CCT and CRI
- Peak Wavelength
- Dominant Wavelength
- I, V, and Luminous Efficacy
APPLICATIONS :
-
Packaged LEDs
- Miniature Lamps
- LED Sourced Systems
|  |
|