Ocean Optics
STS Microspectrometer
Full Spectral Analysis in a Tiny Footprint
The new STS Microspectrometer is a remarkably small CMOS-based unit that is less than 50 mm square and weighs just over 2 ounces/68g.
This ultra-compact spectrometer is ideal for OEM devices and provides full spectral analysis with low stray light and high signal-to-noise ratio.

STS boasts optical resolution of ~1.5 nm (FWHM) and is particularly suited for high-intensity applications such as LED characterization and absorbance/transmission measurements.

Main Features:
  • Dimensions: 40 mm x 42 mm x 24 mm
  • Wavelength range: VIS (350-800 nm), NIR (650-1100 nm)
  • Optical resolution:1.2-1.4 nm FWHM (w/15 µm slit)
  • Dark noise: <3 counts RMS
  • Dynamic range: 6x107 (system, 10s maximum integration)
  • Integration time:1 ms - 10 s
  • Corrected linearity: 0.5% max deviation from best fit line (10-90% saturation)
Applications:
  • Life Science
  • Medial Diagnostic
  • Solid State lighting
  • Environmental Analysis


STS Microspectrometer for OEM Application
STS Microspectrometer for OEM Application

RaySphere

RaySphere is the ideal system for absolute irradiance measurements from 300-1700 nm.
Specifically designed with the qualification of solar flashers, simulators, and filters in mind, RaySphere is small, portable, easy-to-use, and exceeds the requirements for measurement accuracy, repeatability, and wavelength range needed to classify simulators per applicable IEC, JIS, and ASTM standards.

The ideal tool for :
  • R&D Labs
  • Certification Institutes
  • Solar simulator manufacturers
  • PV module manufacturers
  • PV equipment manufacturers
Advantages :
  • Displays the simuliator class, including full spectra data and measurement timing
  • Small and portable
  • Easy-to-use
  • Great accuracy
  • Great repeatability
  • Exceeds requirements of the IEC, JIS, and ASTM standards
  • Easy-to-use software
Features :
  • Optically stabillized integrating sphere
  • TEC-cooled InGaAs detector
  • Back-thinned Silicon detector
  • Advanced photo-triggering electronics
  • Irradiance calibration using a NIST / PTB traceable light source
  • Measurement software
  • Carrying case
  • Optional certification by an accredited (PTB, NIST, CNIM) calibration lab


Product Sheet Raysphere.pdf

Torus Miniature Spectrometer
The Torus Miniature Spectrometer from Ocean Optics is a Visible range (360-825 nm) unit that delivers low stray light and is ideal for measuring color.

Applications :
  • Trace gas amounts in the atmosphere
  • Absorbance of optically dense solutions
  • Precision measurement of LEDs, lasers and other light sources
  • Medical dosimetry in tissue and biological media
  • Fluorescence from solid surfaces, backscattering and fluorescence in solutions and powders
Features:
  • Optical resolution: <2.0 nm FWHM over the spectral range
  • Wavelength range: 360-825 nm
  • Toroidal diffraction grating


TORUS Concave Grating Mini-Spectrometers
Torus Concave Grating Mini-Spectrometers

USB2000+ Miniature Fiber Optic Spectrometer
This innovative combination produces our fastest spectrometer yet and provides resolution to 0.35 nm (FWHM).
  • 1,000 Full Spectra/Second
  • Programmable Microcontroller
  • Modular design
  • User-configured wavelength range and resolution
  • Automatically reads the wavelength calibration coefficients of the spectrometer and configures operating software
  • USB-to-PC interface; no external power requirements
  • RoHS and CE compliance
Application:
  • Chemical
  • biochemical
  • Other applications where fast reactions need to be monitored.


USB2000+ Miniature Fiber Optic Spectrometer
USB2000+ Miniature Fiber Optic Spectrometer

USB4000 Miniature Fiber Optic Spectrometer
The modular USB4000 is responsive from 200-1100 nm and can be configured with various Ocean Optics optical bench accessories, light sources and sampling optics to create application-specific systems.

Features:
  • Detector range: 200-1100 nm
  • Sensitivity: 130 photons/count at 400 nm; 60 photons/count at 600 nm
  • UV enhanced window: Yes, UV4
  • Fiber optic connector: SMA 905 to 0.22 numerical aperture
  • Optical resolution: ~0.3-10.0 nm FWHM (grating dependent)
  • Computer interfaces: USB 2.0 - RS-232
Applications:
  • Absorbance
  • Reflection
  • Emission


USB4000 Miniature Fiber Optic Spectrometer
USB4000 Miniature Fiber Optic Spectrometer

HR2000+ High-Resolution Spectrometer
The HR2000+ Spectrometer integrates a high-resolution optical bench, a powerful 2-MHz analog-to-digital (A/D) converter, programmable electronics, a 2048-element CCD-array detector, and a high-speed USB 2.0 port.
This innovative combination produces and extremely fast spectrometer and provides resolution to 0.035 nm (FWHM).

The HR2000+ is perfect for chemical, biochemical and other applications where fast reactions need to be monitored and fine spectral features need to be resolved.

You can turn your HR2000+ Spectrometer into a 1-channel LIBS System (LIBS2500-1PLUS) with the LIB2500plus Controller.
  • 1,000 Full Spectra/Second
  • Programmable Microcontroller
  • High-resolution Applications
  • HR2000+ Sample Spectrum
  • High-resolution "HR" Optical Bench
  • Plug and Play Operation
  • Optical Bench Options
  • Installation & Operation Manual


HR2000+ High-Resolution Spectrometer
HR2000+ High-Resolution Spectrometer

HR4000 High-Resolution Spectrometer
The HR4000 Spectrometer is our next-generation high-resolution spectrometer. The HR4000 has a 3648-element CCD-array detector from Toshiba that enables optical resolution as precise as 0.02 nm (FWHM).
  • 0.02 nm Optical Resolution (FWHM) Possible
  • Electronic Shutter Prevents Saturation
  • Onboard Microcontroller
  • Plug-and-Play USB Operation
  • Optical Bench Options
  • Installation and Operation Manual
  • Breakout Box Accessory
HR4000 igh-resolution spectrometer is ideal for applications such as:
  • Characterizing lasers
  • Measuring gas absorbance
  • Determining atomic emission lines.


HR4000 High-Resolution Spectrometer
HR4000 High-Resolution Spectrometer

JAZ Spectrometer Suite
JAZ is like nothing you’ve ever seen before - a community of stackable, modular and autonomous components that combine to create a family of smart sensing instruments.

Those unique features and a platform that expands to include a light source, rechargeable Lithium-Ion battery and up to 8 spectrometer modules make Jaz the first analytical instrument easily adaptable for the field, lab or process environment.

New Jaz ULM-200 Universal light meter is pre-configured spectrophotometer is the ideal tool for field and laboratory measurements of any type of lighting.
  • Jaz Spectrometer Module: 14 gratings, UV through Shortwave NIR
  • Jaz OLED Display Module
  • Jaz Ethernet and Memory Module
  • Jaz Light Source Module:UV-VIS deuterium-tungsten halogen


JAZ Spectrometer Suite
Jaz_spectrometer_suite.pdf Jaz-LightMeter-ULM200.pdf

Maya 2000 Serie - Spectrometer for Deep-UV
Maya-series Spectrometers are back-thinned 2D FFT-CCD spectrometers for low light-level, UV-sensitive and other scientific applications.
Advantages of Back-thinned FFT-CCD Detectors:
  • Great native UV response, FFT-CCD detectors do not require UV-sensitive coatings.
  • High peak quantum efficiency (92% for Maya2000, 75% for the Pro)
  • Great signal-to-noise characteristics
  • Low dark current
  • Good signal processing speed.
  • USB 2.0 interface
  • Optical resolution to ~0.035 nm (FWHM); resolution depends on groove density of grating and size of entrance aperture (slit)


Maya 2000 Serie - Spectrometer for Deep-UV
Maya 2000 Serie - Spectrometer for Deep-UV

NIRQuest Spectrometer
NIRQuest spectrometers are ideal for demanding applications ranging from moisture detection and chemical analysis to high-resolution laser and optical fiber characterization.

NIRQuest spectrometers can be customized for a variety of applications by selecting different gratings, slits and optical bench accessories.
  • NIRQUEST512 900-1700 nm, 512-element InGaAs array-Perfect if you need best response at ~1600 nm and optical resolution of ~3.1 nm (FWHM)
  • NIRQUEST512-2.2 900-2200 nm, 512-element InGaAs array-If you require good response across 900-2200 nm without sacrificing optical resolution performance (~4.7 nm)
  • NIRQUEST512-2.5 900-2550 nm, 512-element InGaAs array-If you require good response across 900-2550 nm without sacrificing optical resolution performance (~6.3 nm)
  • NIRQUEST256-2.1 900-2100 nm, 256-element InGaAs array-For good response at higher wavelengths (~1900 nm) and if high optical resolution (~8.0 nm) is not a major consideration
  • NIRQUEST256-2.5 900-2500 nm, 256-element InGaAs array-You require good response at higher wavelengths (peak response is at ~2200 nm) and if high optical resolution (~11.0 nm) is not a major factor


NIRQuest Spectrometer
NIRQuest Spectrometer NIR instrument Application

Optical Transmittance Spectrophotometer

CIE color and transmission measurement that is fast, accurate and easy!
We’ve combined our expertise in miniature spectrometers and precision optics to create a compact system for real-time transmittance measurement of ophthalmic lenses and other optical components.
The Ocean Optics Optical Transmittance Spectrophotometer (OTS) is ideal for in-lab applications where transmittance accuracy (to +/- 1.0%) and precision (+/- 0.1%) are critical.
Common applications include measurement of plastic and glass lenses, as well as optical coatings, windows and filters, and glass and plastic components.

Typical Applications :
  • Tint color : CIE L* a* b*
  • Visual transmittance
  • UV cutoff
  • Dye bath development
  • Sunlens materials
  • Dichroic, bandpass and neutral density filters
  • Process monitoring


otslinecard.pdf

QE65000 Scientific-Grade Spectrometer
The QE65000 Scientific-grade Spectrometer is a novel combination of detector, optical bench and electronics technologies that provides users with a remarkably sensitive system.

New! Optical Bench Enhancements


The great performance of our QE65000 Spectrometer has been been enhanced to provide even more value: lower stray light, improved efficiency in the UV and Shortwave NIR, and better unit-to-unit reproducibility.
For full UV-Shortwave NIR coverage (175 - 100 nm), you'll want to configure your QE65000 with our HC-1 composite grating.

The QE65000 can achieve up to 90% quantum efficiency with high signal-to-noise and rapid signal processing speed.
Ideally suited for low-light level applications such as:
  • Fluorescence
  • DNA sequencing
  • Astronomy
  • Raman spectroscopy.


QE65000 Scientific-Grade Spectrometer
QE65000 Scientific-Grade Spectrometer

Switch to French
 QuickSearch: 
    http://www.spectroscopy-bfioptilas.fr/en/
    >Spectrometers & Monochromators/CCD Spectrometers